DATAFLEX LiYY

DATA CABLES (DATA CABLES)

CPR Class: Eca

APPROPRIATE USE


Flexible data transmission cable for information processing system, office machines, computer systems, suitable as measuring, control and signal cable for electronic control equipments, balances, etc. also as electronic cable in the milliampere range.

CHARACTERISTICS

DESCRIPTION

REFERENCE

Type of cable LiYY
Nominal Voltage 0,14 mm2: 350V ; ≥ 0,25 mm2: 500V (not for power applications)
1
Core Thin raw copper wires EN 60228
2
Insulation PVC TI2 special type EN 50363
3
Sheath PVC TM2 special type, grey colour RAL 7001 o RAL 7032 EN 50363
Temperature range Fixed laying: from -40°C to 80°C, mobile laying: from -5°C to 70°C
Testing voltage Conductor/conductor: 1500 V AC
Minimum banding radius Fixed laying: 4 x external diameter - Mobile laying: 10 x external diameter
Package 100 m thermo-shrinking material coils - Drums

GENERAL REFERENCE


DIN VDE 0812, EN 50575:2014 + EN 50575/A1:2016

CORE IDENTIFICATION


Coloured cores (DIN 47100)

CERTIFICATION DOP


Download the PDF

Download the PDF

DATASHEET


Download the PDF

Download the PDF

Cavi per applicazioni industriali

Our quality certifications