FS18OH2R18 300/500V
SHIELDED CABLES (SHIELDED CABLES)
CPR Class: Cca s3,d1,a3 Under Certification




NO INTERFERENCE

FIRE RETARDANT
APPROPRIATE USE
To be used for signal and command for connection between equipments and control systems. Starting from 1,5qmm can be used for energy transmission as well and for connecting mechanical parts with different kind of equipments, where it is useful to have resistance against electromagnetical interferences. Fixed laying in internal or temporary outdoor use. Buried fixing is not allowed.
CHARACTERISTICS |
DESCRIPTION |
REFERENCE |
|
---|---|---|---|
Type of cable | FS18OH2R18 | ||
Nominal Voltage | Uo/U 300/500 V | ||
1 | Core | Class 5 flexible red copper | CEI EN 60228 |
2 | Insulation | S18 PVC type | CEI EN 50363 |
3 | Antimigrating | PET tape | |
4 | Screening | Braided annealed red copper | |
5 | Sheath | R18 PVC type | CEI EN 50363 |
Temperature range | -10°C/ 70°C | ||
Testing voltage | 2000 V AC | ||
Package | 100 m thermo-shrinking material coils - Drums |
GENERAL REFERENCE
CEI UNEL 35722
CORE IDENTIFICATION
Black cores numbered in white (EN 50334). JZ: with Yellow/Green; OZ: no Yellow/Green