DATAFLEX Li2YCYv (TP)
DATA CABLES (DATA CABLES)
CPR Class: Eca
NO INTERFERENCE
APPROPRIATE USE
To be used in data processing systems with transmissions up to 10 Mbits/s, suitable for low sensible signals at high speed. Compatible with RS422 and RS485. Suitable for fixed laying or occasional movements. Both for inside or outside installations. Resistant black outer sheat (Yv).
CHARACTERISTICS |
DESCRIPTION |
REFERENCE |
|
---|---|---|---|
Type of cable | Li2YCYv (TP) | ||
Nominal Voltage | Uo/U 250V (not for power applications) | ||
1 | Core | 7 wires raw stranded copper | VDE 0881 |
2 | Insulation | Polyethylene (PE) | |
3 | Antimigrating | PET tape | |
4 | Screening | Screening braid of tinned copper wires | |
5 | Sheath | Strengthened PVC black colour RAL 9005 or blue colour RAL 5015 | EN 50363 |
Temperature range | Fixed laying: from -30°C to 80°C, random mobility: from -5°C to 70°C | ||
Testing voltage | Conductor/conductor: 2000 V AC - Conductor/shield: 1000 V AC | ||
Minimum banding radius | Fixed laying: 6 x external diameter - Mobile laying: 15 x external diameter | ||
Package | 100 m thermo-shrinking material coils - Drums |
GENERAL REFERENCE
VDE 0812
CORE IDENTIFICATION
Coloured cores (DIN 47100)