DATAFLEX Li2YCY (TP)
DATA CABLES (DATA CABLES)
CPR Class: Eca Under Certification
NO INTERFERENCE
APPROPRIATE USE
To be used in data processing systems with transmissions up to 10 Mbits/s, suitable for low sensible signals at high speed. Compatible with RS422 and RS485. Suitable for fixed laying or occasional movements. Can be installed in both dry and wet environments.
CHARACTERISTICS |
DESCRIPTION |
REFERENCE |
|
---|---|---|---|
Type of cable | Li2YCY (TP) | ||
Nominal Voltage | Uo/U 250V (not for power applications) | ||
1 | Core | 7 wires raw stranded copper | VDE 0881 |
2 | Insulation | Polyethylene (PE) | |
3 | Antimigrating | PET tape | |
4 | Screening | Screening braid of tinned copper wires | |
5 | Sheath | PVC TM2 special type, grey colour RAL 7001 o RAL 7032 | EN 50363 |
Temperature range | Fixed laying: from -30°C to 80°C, random mobility: from -5°C to 70°C | ||
Testing voltage | Conductor/conductor: 2000 V AC - Conductor/shield: 1000 V AC | ||
Minimum banding radius | Fixed laying: 6 x external diameter - Mobile laying: 15 x external diameter | ||
Package | 100 m thermo-shrinking material coils - Drums |
GENERAL REFERENCE
VDE 0812
CORE IDENTIFICATION
Coloured cores (DIN 47100)