FS18OH2R18 300/500V

SHIELDED CABLES (SHIELDED CABLES)

CPR Class: Cca s3,d1,a3 Under Certification

NO INTERFERENCE

FIRE RETARDANT

APPROPRIATE USE


To be used for signal and command for connection between equipments and control systems. Starting from 1,5qmm can be used for energy transmission as well and for connecting mechanical parts with different kind of equipments, where it is useful to have resistance against electromagnetical interferences. Fixed laying in internal or temporary outdoor use. Buried fixing is not allowed.

CHARACTERISTICS

DESCRIPTION

REFERENCE

Type of cable FS18OH2R18
Nominal Voltage Uo/U 300/500 V
1
Core Class 5 flexible red copper CEI EN 60228
2
Insulation S18 PVC type CEI EN 50363
3
Antimigrating PET tape
4
Screening Braided annealed red copper
5
Sheath R18 PVC type CEI EN 50363
Temperature range -10°C/ 70°C
Testing voltage 2000 V AC
Package 100 m thermo-shrinking material coils - Drums

GENERAL REFERENCE


CEI UNEL 35722

CORE IDENTIFICATION


Black cores numbered in white (EN 50334). JZ: with Yellow/Green; OZ: no Yellow/Green

DATASHEET


Download the PDF

Download the PDF